TM 9-2320-312-24-1
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 3. Cab Tilt System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
CAB TILT SYSTEM (POWERED OPERATION)
Cab Will Not Tilt/Lower.
1. Check hydraulic fluid level in
Add hydraulic fluid as required
cab tilt pump (WP 0125 00).
a. Tighten any loose or
2. Inspect cab tilt system hoses
leaking fitting.
and fittings for signs of
leaking or damage.
b. Replace damaged hoses
or fittings (WP 0126 00).
Tighten, repair or replace loose,
3. Use multimeter to check
wires and connectors between
damaged or corroded wires and
battery box and cab tilt
connectors (WP 0120 00).
electric motor.
4. Use multimeter to test cab tilt
Replace cab tilt motor and pump
motor switch (WP 0124 00).
assembly if no pumping action is
apparent (WP 0124 00).
a. Replace failed circuit
5. Use multimeter to test 40A
breaker or relay (WP 0124
circuit breaker and relay,
located in cab tilt pump box.
b. Replace cab tilt motor and
pump assembly if no
pumping
action
is
apparent (WP 0124 00).
Table 4. Electrical System Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
BATTERY SYSTEM
1. Batteries Fail to Maintain Charge.
1. Check level of electrolyte in
Service batteries as required
batteries.
2. Check batteries posts and
Service batteries as required
cables for corrosion.
3. Inspect for loose or damaged
a. Tighten loose battery
battery cables.
cables (WP 0115 00).
b. Replace damaged battery
cables (WP 0115 00).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |