Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check for loose, broken or 1. Adjust loose V-belts (WP 0069
10. No Alternator Output.
missing alternator belts.
2. Replace broken or missing V-
belts (WP 0069 00).
2. Test alternator circuit voltage
a. Place battery disconnect
switch in OFF position.
b. Set
to
appropriate voltage range.
c. Connect meter positive
lead to orange lead
disconnected
from
alternator positive terminal
and meter negative lead to
chassis ground.
386-053
d. Place battery disconnect 1. If battery voltage is not
switch to ON position.
indicated, repair or replace
alternator-to-ammeter wiring
e. If battery voltage is 2. Repair or replace alternator
ground (WP 0177 00).
indicated, place battery
disconnect switch in OFF
position
|