TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
b. Connect
7.
Batteries Hot or Boiling, Corrected Specific
directly across battery
Gravity of All Cells is 1.240 - Continued.
terminals as shown.
c. Start engine and allow it to If meter does not indicate 26.6-
stabilize at 2000-2090 28.3 volts, replace alternator (WP
RPM.
386-497
1. Visually inspect batteries for Replace batteries as required (WP
8.
Batteries Use Excessive Water.
leaks.
2. Test charging voltage. Go to
Table 6, Malfunction 7.
1. Check for loose, broken or 1. Adjust loose V-belts (WP 0069
9.
Batteries Run Down in Service.
missing alternator belts.
2. Replace broken or missing V-
belts (WP 0069 00).
2. Test charging voltage. Go to
Table 6, Malfunction 7.
|