Page Title: ELECTRICAL GENERAL MAINTENANCE INSTRUCTIONS
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2410-233-23
ELECTRICAL GENERAL MAINTENANCE INSTRUCTIONS
THIS WORK PACKAGE COVERS
Splicing Wires
Receptacle Connector Repair
Electrical Ground Points
Waterproof Connector Repair
Military Connector Repair
Relay Inspection and Test
Ring Terminal Repair
INITIAL SETUP
Materials/Parts - Continued
Tools and Special Tools
Tool kit, general mechanic's (Item 112, WP 0185
Grease, electrically conductive (Item 16, WP 0184
Shop equipment, common no. 1 (Item 94, WP 0185
Insulating sleeving (Item 17, WP 0184 00)
Materials/Parts
Insulating varnish, electrical (Item 18, WP 0184 00)
Cloth, abrasive (Item 5, WP 0184 00)
Solder, lead-tin alloy (Item 34, WP 0184 00)
Detergent (Item 10, WP 0184 00)
Tag, marker (Item 35, WP 0184 00)
Flux, soldering (Item 11, WP 0184 00)
NOTE
Use electrically conductive grease on unprotected (exposed to weather) electrical connectors
before connections are made.
Use electrical insulating varnish on all electrical connections that are mounted outside of
machine and are exposed to harsh weather and/or spray from the ground.
Tag and mark position of wires in electrical connector to ensure correct installation.