TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
f. Check continuity between 3. If wiring to chassis ground is
10. No Alternator Output - Continued.
OK, replace alternator (WP
alternator and ground (WP
11. Alternator Output Low (Ammeter Reading 1. Check for loose, broken or 1. Adjust loose V-belts (WP 0069
missing alternator belts.
in Red Zone).
2. Replace broken or missing V-
belts (WP 0069 00).
2. Test charging voltage. Go to
Table 6, Malfunction 7.
Table 6, Malfunction 7.
High Green Zone).
2. Check
for
overheating.
a. Run
engine
for
approximately 10 minutes.
If alternator is hot, place battery
b. With engine off, check
disconnect switch to OFF
for
high
position and allow alternator to
temperature by holding
cool.
hand near alternator.
c. Restart engine.
If ammeter returns to high green
zone and alternator heats up
again, replace alternator (WP
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |