TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a. Set
multimeter
to
3.
Engine Will Not Crank - Continued.
appropriate voltage range
b. Connect
multimeter
positive lead to solenoid
terminal BAT and negative
lead to ground strap.
c. Place battery disconnect
switch in ON position.
Multimeter should read
battery voltage.
d. With  multimeter  still Recharge batteries if voltage
connected as above, place reading is low. Each cell of
light switch to ON position battery must show 1.6 volts.
for  approximately  15
seconds.
Multimeter
reading should not be
below 18 volts.
3. Test starting motor. Go to
Table 6, Malfunction 5.
1. Test
battery
disconnect
4.
All Tractor Electrical Systems Inoperative.
switch for continuity.
a. Place battery disconnect
switch in OFF position.
b. Disconnect
negative
battery cable from battery
c. Disconnect cables from
battery disconnect switch
d. Set  multimeter  to  the
appropriate ohm (Ω) range
e. Connect
multimeter
between battery disconnect
switch terminals.