TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
f. Place battery disconnect If continuity is not indicated,
4.
All Tractor Electrical Systems Inoperative -
switch in ON position.
replace battery disconnect switch
Continued.
2. Check connection of battery Clean and/or reconnect battery
cables and condition of cables if necessary (WP 0080 00).
terminals. Check that battery
is correctly connected to
batteries, starting motor and
chassis ground.
3. Perform Table 6, Malfunction
3, Test 1.
STARTING SYSTEM
24 VOLTS
AUX
START
RECEPTACLE
PRESSURE
SWITCH
START
STARTER
SW
BYPASS
CIRCUIT
BREAKER
386-481
STARTING
MOTOR
0006 00-24
|