TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Fill each cell to fill ring with
c. Check electrolyte level in
3. Engine Will Not Crank - Continued.
distilled water.
each battery cell (TM 9-
6410-200-14).
1. Charge all batteries not
d. Perform specific gravity
test (TM 9-6410-200-14).
meeting requirements and
Batteries must test 1.240 or
recheck specific gravity.
greater,
temperature
corrected, and each cell in
2. If 25 point variation still exists,
battery must test within 25
replace battery (WP 0080 00).
points of the others.
WARNING
Touch terminal connections one at a time; never touch both
terminals at once. Be sure not to be grounded to the machine
when checking. Failure to do so may cause serious injury or
death to personnel.
e. Attempt to crank engine for 1. Tighten all loose connections
at batteries.
15 seconds. Place battery
disconnect switch in OFF
position and feel battery 2. Tighten battery ground wire at
tractor chassis ground. Tighten
terminal connections.
battery positive wire at starter
solenoid. Go to Malfunction 3,
Test 2.
2. Test batteries under load to
determine adequate current
capability and voltage drop
during a 15 second amperage
load.
g
S
MTR
(+)
(-)
BAT
386-479
0006 00-22
|