TM 9-2320-364-34-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits a direct short may result. Damage to equipment, injury or death to personnel may result.
Do not stand under crane. Mechanical failure and operator error can cause injury or death to
personnel.
BOOM
MAGNETIC
PROTRACTOR
ADJUSTMENT TEST
(1) Loosen screw at bottom of angle
sensor.
(2) Attempt to adjust angle sensor so that
actual angle (indicated by magnetic
protractor) and angle indicated on test
unit display are the same.
BOOM
(3) Tighten screw.
(a) If it is not possible to adjust
angle sensor enough that test unit
indicates actual angle, remove
magnetic protractor from boom
and replace OSS box (Para 6-8).
(b) If test unit indicates actual angle,
angle sensor is OK. Remove
magnetic protractor from boom
and go to Step 14 of this Fault.
SCREW
ANGLE
SENSOR