|
|
TM 9-2320-364-34-1
21. CRANE FAILS LOAD TEST (CONT).
10.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Unit Troubleshooting
Adjustment test.
on Page 2-697
tasks completed.
OSS box is grounded.
REASON FOR QUESTION
Hoist proximity sensor OK.
Can OSS box be adjusted into
If OSS box is out of calibration,
calibration?
adjusting OSS should bring it
POSSIBLE PROBLEMS
back into calibration. If OSS box
is faulty, it will not be possible to
OSS box out of adjustment.
adjust it back into calibration.
OSS box faulty.
Replace OSS box
(Para 6-8).
NO
Verify repair, go to
Step 14 of this Fault.
YES
Verify repair, go to
Step 14 of this Fault.
2-696
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |