TM 9-2320-364-34-1
21. CRANE FAILS LOAD TEST (CONT).
11.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Unit Troubleshooting
Adjustment test.
on Page 2-699
tasks completed.
OSS box is grounded.
REASON FOR QUESTION
Hoist proximity sensor OK.
Can OSS box be adjusted into
If OSS box is out of calibration,
calibration?
POSSIBLE PROBLEMS
adjusting OSS should bring it
back into calibration. If OSS box
OSS box out of adjustment.
is faulty, it will not be possible to
OSS box faulty.
adjust it back into calibration.
Replace OSS box
(Para 6-8).
NO
Verify repair, go to
Step 14 of this Fault.
YES
Verify repair, go to
Step 14 of this Fault.