Page Title: FAN, LHS, WINCH AND CRANE DO NOT OPERATE OR OPERATE SLOWLY. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
High pressure hydraulics [oil under 3675 psi (25,339 kPa) pressure] operate this equipment. Refer to
vehicle operator and maintenance manuals for hydraulic oil pressure. Never disconnect any hydraulic
line or fitting without first dropping pressure to zero. Failure to comply may result in injury to
personnel.
Fuel and oil are slippery and can cause falls. To avoid injury, wipe up spilled fuel or oil with rags.
PRESSURE TEST
(1) Refer to Para 17-5 and check main
hydraulic pump output pressure.
(a) If 3,675 +75, - 50 psi (25,339
-
+517, - 345 kPa) are not present
-
on flowmeter pressure gage when
flow drops to 0 gpm ( 0 lpm),
adjust or replace hydraulic
pump control (Para 17-5).
(b) If 3,675 +75, - 50 psi (25,339
-
+517, - 345 kPa) are present,
-
hydraulic pump control is OK.
(2) Check main hydraulic reservoir oil
level and add oil as necessary
(TM-9-2320-364-20).