2. FAN, LHS, WINCH AND CRANE DO NOT OPERATE
OR OPERATE SLOWLY (CONT).
3.
TEST OPTIONS
KNOWN INFO
Verify repair.
Unit Troubleshooting
Do fan, LHS, winch and crane
tasks completed.
operate correctly?
REASON FOR QUESTION
Main hydraulic pump OK.
Hydraulic pump control OK.
If fan, LHS, winch and crane
operate correctly, fault has been
POSSIBLE PROBLEMS
corrected.
Fault not corrected.
NO
Notify supervisor.
YES
Fault corrected.
2-200