Click here to make tpub.com your Home Page

Page Title: FAN, LHS, WINCH AND CRANE DO NOT OPERATE OR OPERATE SLOWLY. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
2. FAN, LHS, WINCH AND CRANE DO NOT OPERATE
OR OPERATE SLOWLY (CONT).
2.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Unit Troubleshooting
Pressure test.
tasks completed.
Main hydraulic pump OK.
REASON FOR QUESTION
Is main hydraulic pump
Faulty or misadjusted hydraulic
POSSIBLE PROBLEMS
control adjusted correctly?
pump control will not allow main
Hydraulic pump control faulty.
hydraulic pump to supply
fluid for correct hydraulic system
operation.
Adjust or replace
hydraulic pump
control
NO
(Para 17-5 or 17-2).
Verify repair, go to
Step 3 of this Fault.
YES
2-198