TM 9-2320-364-34-1
2. FAN, LHS, WINCH AND CRANE DO NOT OPERATE
OR OPERATE SLOWLY (CONT).
2.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Unit Troubleshooting
Pressure test.
on Page 2-199
tasks completed.
Main hydraulic pump OK.
REASON FOR QUESTION
Is main hydraulic pump
Faulty or misadjusted hydraulic
POSSIBLE PROBLEMS
control adjusted correctly?
pump control will not allow main
Hydraulic pump control faulty.
hydraulic pump to supply
fluid for correct hydraulic system
operation.
Adjust or replace
hydraulic pump
control
NO
(Para 17-5 or 17-2).
Verify repair, go to
Step 3 of this Fault.
YES
2-198
|