![]() TM 9-2320-363-20-2 
FAN TEMPERATURE SENSOR REPLACEMENT 
This task covers: 
a. Removal 
b. Cleaning/Inspection 
c. Installation 
INITIAL SETUP 
Tools and Special Equipment: 
Equipment Condition: 
Tool Kit, SC 5180-90-CL-N26 
Reference 
Condition Description 
Materials/Parts: 
Thermostat Housing 
Drained 
Washer, Lock (2) 
P/N 3059-00874-02 
Page 2-29 
Batteries Disconnected 
Compound, Pipe 
Appendix C, Item 8 
Sealing 
References: 
TM 9-2320-363-20-1 
REMOVAL 
1. 
REMOVE TWO SCREWS (1) AND TWO LOCK WASHERS (2) AND DISCONNECT TWO WIRES (3) FROM 
SENSOR (4). DISCARD LOCK WASHERS. 
2. 
REMOVE SENSOR (4) FROM THERMOSTAT HOUSING (5). 
4-236 Change 3 
 | 
| 
 