10. 
INSTALL TWO TEMPERATURE SENDING UNITS (6 AND 7) IN THERMOSTAT HOUSING COVER (2). 
NOTE 
Make sure machined mating surfaces of thermostat housing cover and cylinder 
head are clean and dry. 
11. 
INSTALL THERMOSTAT HOUSING COVER (2) ON CYLINDER HEAD (8) AND INSTALL FOUR BOLTS (9). 
TIGHTEN BOLTS TO 43-54 LB-FT (58-73 N.m). 
12. 
INSTALL TWO WIRES (10), TWO NEW LOCK WASHERS (11), AND TWO SCREWS (12) ON TEMPERATURE 
SENDING UNIT (7). 
13. 
INSTALL WIRE (13), NEW LOCK WASHER (14), AND NUT (15) ON TEMPERATURE SENDING UNIT (6). 
NOTE 
Follow-on Maintenance: 
Connect hoses and lines to thermostat housing cover (page 4-116). 
Fill cooling system (Unit PMCS, TM 9-2320-363-20-1). 
Change 3 4-131 
 | 
| 
 