THERMOSTAT AND THERMOSTAT HOUSING COVER REPLACEMENT (CONT)
INSTALLATlON
INSTALL TWO PIPE PLUGS (1) IN THERMOSTAT HOUSING COVER (2).
1.
INSTALL DRAINCOCK (3) IN BOTTOM OF THERMOSTAT HOUSING COVER (2).
2.
SUPPORT THERMOSTAT HOUSING COVER (2), CONTACT SIDE UP, ON WORKBENCH SO IT IS
3.
LEVEL.
4.
USING INSTALLER (P/N J8550) AND HANDLE (P/N J7079-2), INSTALL NEW THERMOSTAT SEAL
(4) ON INSTALLER (P/N J8550) AND INSERT INTO THERMOSTAT HOUSING COVER (2) BORE.
USING HAMMER, DRIVE THERMOSTAT SEAL (4) INTO THERMOSTAT HOUSING COVER (2) BORE
5.
UNTIL TOOL LIP IS FLUSH AGAINST HOUSING COVER (2).
REPEAT STEPS 4 AND 5 TO INSTALL REMAINING NEW THERMOSTAT SEAL (4).
6.
7.
LUBRICATE LIPS OF BOTH THERMOSTAT SEALS (4) WITH THIN FILM OF CLEAN ENGINE
LUBRICATING OIL.
INSTALL THERMOSTAT (5) IN THERMOSTAT HOUSING COVER (2), SPRING SIDE UP, AND
8.
PRESS INTO HOUSING COVER (2) WITH HEEL OF HAND.
REPEAT STEP 8 TO INSTALL REMAINING THERMOSTAT (5).
9.