TM 9-2320-360-34-2
(3) Measure spring lengths using spring tester (1).
Converter bypass valve spring, lockup shift
valve spring, and main pressure regulator valve
spring must be replaced if load-height
specifications, listed in table 22-1, are not met.
(4) Inspect two oil pump shafts (2). Replace oil
pump assembly if shafts are worn or damaged.
Table 22-1. Valve Spring Load-Height Specifications
Spring
Length Without Load
Length Under Load
Load
Converter
2.65 in.
1.62 in.
21 to 23 lb
bypass valve
(67.3 mm)
(41.2 mm)
(9.6 to 10.4 kg)
Lockup shift
3.33 in.
1.8 in.
24 to 25.5 lb
valve
(84.6 mm)
(45.7 mm)
(10 to 10.9 kg)
Main regulator
3.94 in.
2.64 in.
82 to 87 lb
valve
(100.1 mm)
(67.1 mm)
(37.2 to 39.4 kg)
d. Assembly
(1) install bearing (1) in ground sleeve bore (2)
using bearing installer tool (3) and driver handle
(4).
22-29
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |