TM 9-2320-360-34-2
22-7. TORQUE CONVERTER HOUSING/FRONT SUPPORT REPAIR (CONT)
(22)
Remove front support assembly (35) from
torque converter housing (1).
(23)
Remove gasket (38) from torque
converter housing (1). Discard gasket
(24)
Remove bearing (39) from ground sleeve
bore (40) using bearing remover tool (41).
(25)
Remove pin (43), shifter valve (44), and
spring (45) from torque converter housing
(1) using valve pin remover (42) and slide
hammer (42.1).
c.
Cleaning/lnspection
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles and
gloves and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and don't breathe vapors. DO NOT use near open flame or excessive heat.
o
o
The flash point is 100-138 F (38-59 C). If you become dizzy while using cleaning
solvent, get fresh air immediately and medical aid. If contact with eyes is made,
wash your eyes with water and get medical aid immediately.
(1)
Clean metal parts with dry cleaning solvent and inspect for damage.
WARNING
Compressed air for cleaning purposes will not exceed 30 psi (207 kPa). Use only
with effective chip guarding and personal protective equipment (goggles/shield,
gloves, etc.).
(2)
Dry metal parts with compressed air.
22-28 Change 1
|