TM 9-2320-312-24-2
Truck Engine
Disassembly and Assembly Section
i01481332
Atmospheric Pressure Sensor
- Remove and Install
SMCS Code: 1923-010
Removal Procedure
NOTICE
Keep all parts clean from contaminants.
Contaminants may cause rapid wear and shortened
component life.
g00772510
Illustration 241
(1) Atmospheric pressure sensor
NOTICE
Care must be taken to ensure that fluids are contained
1. Install atmospheric pressure sensor (1). Tighten
during performance of inspection, maintenance, test-
the atmospheric pressure sensor to a torque of
ing, adjusting and repair of the product. Be prepared to
10 2 Nm (90 18 lb in).
collect the fluid with suitable containers before open-
ing any compartment or disassembling any compo-
2. Connect the plug for atmospheric pressure
nent containing fluids.
sensor (1).
Refer to Special Publication, NENG2500, "Caterpillar
i01748101
Tools and Shop Products Guide" for tools and supplies
suitable to collect and contain fluids on Caterpillar
Coolant Temperature Sensor -
products.
Remove and Install
Dispose of all fluids according to local regulations and
SMCS Code: 1906-010
mandates.
Removal Procedure
NOTICE
Keep all parts clean from contaminants.
Contaminants may cause rapid wear and shortened
component life.
NOTICE
Care must be taken to ensure that fluids are contained
during performance of inspection, maintenance, test-
ing, adjusting and repair of the product. Be prepared to
collect the fluid with suitable containers before open-
g00772510
Illustration 240
ing any compartment or disassembling any compo-
(1) Atmospheric pressure sensor
nent containing fluids.
1. Disconnect the plug for atmospheric pressure
Refer to Special Publication, NENG2500, "Caterpillar
sensor (1).
Tools and Shop Products Guide" for tools and supplies
suitable to collect and contain fluids on Caterpillar
2. Remove atmospheric pressure sensor (1).
products.
Dispose of all fluids according to local regulations and
Installation Procedure
mandates.
NOTICE
Keep all parts clean from contaminants.
Contaminants may cause rapid wear and shortened
component life.