AIR SYSTEM TROUBLESHOOTING
THIS WORK PACKAGE COVERS
Air System Troubleshooting Procedures
INITIAL SETUP
Maintenance Level
Tools and Special Tools
Unit
Tool kit, general mechanic's (Item 102, WP 0313
Table 1. Air System Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Loss Of Air Pressure.
1. Check for leaks in lines and Replace damaged components
fittings.
2. Check for faulty air supply Replace damaged components
tanks or components.
2.
Loss Of Air Supply Function.
1. Check for blocked or kinked Replace damaged lines (WP 0138
lines.
2. Check for faulty valves.
Replace faulty valves (WP 0133
3.
Air Dryer Leaks.
Check for faulty seal.
Replace filter seal (WP 0135 00).
4.
Air Dryer Fails To Absorb Pollutants.
1. Check for dirty filter(s).
Service (WP 0135 00) or replace
air dryer (WP 0134 00).
2. Check
for
contaminated Service (WP 0135 00) or replace
desiccant beads (drying beads). air dryer (WP 0134 00).
3. Check for faulty purge valve.
Service (WP 0135 00) or replace
air dryer (WP 0134 00).