Click here to make tpub.com your Home Page

Page Title: PRIMARY II AIR TANK AND FITTINGS REPLACEMENT
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-303-24-1
PRIMARY II AIR TANK AND FITTINGS REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Maintenance Level
Materials/Parts - Continued
Nut, lock (P/N M45913/1-6CG5C) (4)
Unit
References
Tools and Special Tools
TM 9-2320-303-10
Tool kit, general mechanic's (Item 102, WP 0313
Materials/Parts
Equipment Condition
Tags, marker (Item 42, WP 0312 00)
Air system drained (TM 9-2320-303-10)
Spare tire removed (TM 9-2320-303-10)
Compound, pipe, sealing (Item 17, WP 0312 00)
WARNING
Make sure all air lines and fittings are clear of debris. Make sure excess pipe sealant compound does not
enter air lines or fittings. Failure to do so could result in equipment failure and/or injury to personnel.
Sealant compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing.
To avoid injury or death, keep away from open fire and use in well-ventilated area. If sealant compound
gets on skin or clothing, wash immediately with soap and water.

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business