TM 5-2420-224-34
PAVEMENT BREAKER REPAIR (CONT)
W h e n discharging nitrogen from
a c c u m u l a t o r , stand to one side
a n d keep face away from front
of charging valve to prevent
p e r s o n a l injury.
e . Discharge accumulator assembly (17)
completely.
INSTALL new backup washer (19) and new
8.
c u p SEAL (20), with lips facing out, in
accumulator chamber (14).
9. INSTALL new PACKING (21) on accumulator
cylinder (16).
PRESS,
INSTALL
10. USING
suitable
ACCUMULATOR assembly (17) in handle
(22).