TM 5-2420-224-34
Table 2-1. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
CRANE (CONT)
NOTE
Monitor oil temperature during entire test. Do not allow oil temperature to exceed 140F
(60C). Failure to do so may result in incorrect readings of flow rate.
f.
Cycle oil until oil is at operating temperature of 120F (49C).
g. Close load valve until 1000 psi (69 bar) is noted on flow meter.
h. Open load valve until 0 psi (0 bar) is noted on flow meter.
i.
Close load valve until 1500 psi (103.4 bar) is noted on flow meter.
Open load valve until 0 psi (0 bar) is noted on flow meter.
j.
k. Close load valve until 2000 psi (137.9 bar) is noted on flow meter. Flow
rate at this time should be 9 gpm (34 Ipm).
If flow rate is not 9 gpm (34 Ipm), replace flow regulating
valve (page 11-22).
38. CRANE OPERATION SLOWS DOWN.
Perform Malfunction 37, step 3.
Check holding valve on noisy cylinder as follows:
a.
Lift maximum load for crane approximately 6-8 in. off ground.
b. Extend outer boom to its maximum.
c.
Shut off engine.
d. Monitor down drift of load for approximately 10 minutes.
If there is any down drift of load, replace holding valve on
cylinder that drifts down.
FRONT LOADER
Check for worn or damaged parts in mechanical detent. If parts are worn or
damaged, adjust float detent as follows:
|