Page Title: CRANE FLOW REGULATING VALVE REPLACEMENT
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2420-224-34
CRANE
FLOW
REGULATING
VALVE
REPLACEMENT
a. Removal b. Installation
This task covers:
INITIAL SETUP
Equipment Condition:
Applicable Configuration:
HMMH
Reference
Condition Description
Crane in Three-Point
TM 5-2420-224-20
Tools and Special Equipment:
Stance
Shop Equipment, SC 4910-95-CL-A31
Hydraulic Pressure
TM 5-2420-224-20
Tool Kit, SC 5180-90-CL-N26
Relieved
Materials/Parts:
General Safety Instructions:
Packing
Packing
WARNING
Packing
High pressure hydraulics [oil
under 2450 psi (16,893 kPa)]
Caps and Plugs
operate  this  equipment.
Rags
Never  disconnect  any
hydraulic  line  or  fitting
References:
without  first  dropping
pressure to zero. A high
TM 5-2420-224-20
pressure  oil  stream  can
pierce  body  and  cause
severe injury to personnel.
Fuel and oil are slippery and
can cause falls. To avoid
injury, wipe up spilled fuel or
oil with rags.
REMOVAL
CAUTION
C a p or plug all ports and ends of hoses and tubes to prevent contamination of
h y d r a u l i c oil. Failure to do so may result in damage to equipment.
DISCONNECT hydraulic HOSE (1), elbow (2), and tee (3). INSTALL CAP or PLUG.
1.
REMOVE two bolts (4) and flow regulating VALVE (5).
2.
REMOVE two ADAPTERS (6 and 7), elbow (8), and three packings (9, 10, and 11). DISCARD
3.
PACKINGS.
--