TM 5-2420-224-34
CRANE
FLOW
REGULATING
VALVE
REPLACEMENT
a. Removal b. Installation
This task covers:
INITIAL SETUP
Equipment Condition:
Applicable Configuration:
HMMH
Reference
Condition Description
Crane in Three-Point
TM 5-2420-224-20
Tools and Special Equipment:
Stance
Shop Equipment, SC 4910-95-CL-A31
Hydraulic Pressure
TM 5-2420-224-20
Tool Kit, SC 5180-90-CL-N26
Relieved
Materials/Parts:
General Safety Instructions:
Packing
Packing
WARNING
Packing
High pressure hydraulics [oil
under 2450 psi (16,893 kPa)]
Appendix B, Item 8
Caps and Plugs
operate this equipment.
Appendix B, Item 40
Rags
Never disconnect any
hydraulic line or fitting
References:
without first dropping
pressure to zero. A high
TM 5-2420-224-20
pressure oil stream can
pierce body and cause
severe injury to personnel.
Fuel and oil are slippery and
can cause falls. To avoid
injury, wipe up spilled fuel or
oil with rags.
REMOVAL
CAUTION
C a p or plug all ports and ends of hoses and tubes to prevent contamination of
h y d r a u l i c oil. Failure to do so may result in damage to equipment.
DISCONNECT hydraulic HOSE (1), elbow (2), and tee (3). INSTALL CAP or PLUG.
1.
REMOVE two bolts (4) and flow regulating VALVE (5).
2.
REMOVE two ADAPTERS (6 and 7), elbow (8), and three packings (9, 10, and 11). DISCARD
3.
PACKINGS.
--
|