TM 5-2420-222-20-1
THERMOSTAT - CONTINUED
INSTALLATION - CONTINUED
NOTE
FOLLOW-ON MAINTENANCE:
1.
Fill radiator (page 2-368).
2.
Install hood (page 2-1025).
TASK ENDS HERE
THERMOSTAT HOSES AND CLAMPS
This task covers:
a. Removal (page 2-400)
c.
Inspection/Replacement (page 2-402)
b. Cleaning (page 2-401)
d.
Installation (page 2-402)
INITIAL SETUP
Tools
Personnel Required
Screwdriver, flat-tip, 3/16-inch
One
Materials/Parts
Equipment Condition
Detergent, GP (item 7, Appendix C)
1. Hood removed (page 2-1025)
Rags, wiping (item 21, Appendix C)
2. Radiator drained (page 2-368)
Solvent, drycleaning
(item 28, Appendix C)
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
NOTE
Serial Numbers 235786 thru 235999 use an L-shaped preformed hose. Serial Numbers 319995 thru
342573 use a straight hose.
1. Preformed hose (1)
Two clamps (3)
Using 3/16-inch flat-tip screwdriver,
or straight hose (2)
loosen.