Page Title: THERMOSTAT HOSES AND CLAMPS
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2420-222-20-1
THERMOSTAT - CONTINUED
INSTALLATION - CONTINUED
NOTE
FOLLOW-ON MAINTENANCE:
1.
Fill radiator (page 2-368).
2.
Install hood (page 2-1025).
TASK ENDS HERE
THERMOSTAT HOSES AND CLAMPS
This task covers:
a. Removal (page 2-400)
c.
Inspection/Replacement (page 2-402)
b. Cleaning (page 2-401)
d.
Installation (page 2-402)
INITIAL SETUP
Tools
Personnel Required
Screwdriver, flat-tip, 3/16-inch
One
Materials/Parts
Equipment Condition
Detergent, GP (item 7, Appendix C)
1. Hood removed (page 2-1025)
Rags, wiping (item 21, Appendix C)
2. Radiator drained (page 2-368)
Solvent, drycleaning
(item 28, Appendix C)
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
NOTE
Serial Numbers 235786 thru 235999 use an L-shaped preformed hose. Serial Numbers 319995 thru
342573 use a straight hose.
1. Preformed hose (1)
Two clamps (3)
Using 3/16-inch flat-tip screwdriver,
or straight hose (2)
loosen.
2-400