TM 5-2420-222-20-1
THERMOSTAT - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
11.
New gasket (3)
Put in place.
and cover (4)
12. Cover (4) and
Clamp (6)
Put in place.
injection leakoff
fuel tube (5)
13 Cover (4),
Two screws (7)
a. Screw In and alternately tighten until
clamp (6), and
snug using 9/16-inch, 3/8-inch drive
thermostat
socket and ratchet handle.
housing (2)
b. Using 0 to 60 N.m capacity 3/8-inch
drive torque wrench, tighten to 20 foot-
pounds (27.1 N.m) torque.
14. Cover (4)
Upper radiator
Push on.
hose (8) with
assembled clamp (9)
15. Upper radiator
Clamp (9)
Using 3/16-inch flat-tip screwdriver,
hose (8)
tighten.
2-399
|