TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
c. Observe
multimeter 1. If continuity is indicated,
5.
Starting Motor Inoperative - Continued.
reading.
replace starting motor solenoid
2. If no continuity is indicated,
repair the ground circuit (WP
G
S
MTR
(+)
(-)
BAT
386-485
7. Test starter relay.
a. Place battery disconnect
switch in OFF position.
b. Set
to
appropriate voltage range.
c. Connect
positive lead to smaller
gage wire with no
insulation and negative
lead to chassis ground.
d. Place battery disconnect
switch in ON position.
0006 00-29
|