TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e. Momentarily turn start 1. If voltage is indicated, go to
5.
Starting Motor Inoperative - Continued.
Table 6, Malfunction 5, Test 6.
switch fully to the right and
observe
reading.
2. If voltage is not indicated, go
to Table 6, Malfunction 5, Test
7.
G
S
MTR
(+)
(-)
BAT
386-484
6. Test G terminal for continuity
to ground.
a. Place battery disconnect
switch in OFF position.
b. Connect meter positive
lead to G terminal on
solenoid and negative lead
to chassis ground.
0006 00-28
|