TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check circuit breakers
Reset circuit breakers.
5.
Starting Motor Inoperative.
2. Test solenoid operation.
a. Place battery disconnect 1. If thump of starter solenoid
energizing is heard, go to
switching in ON position.
Test b.
Turn start switch fully to
the right and listen for
starting motor solenoid to
energize.
2. If thump of starter solenoid
energizing is not heard, go to
Malfunction 5, Test 3.
b. Place battery disconnect
switch in OFF position.
c. Check continuity of L- 1. If no continuity is indicated,
repair connection (WP 0177
shaped connector between
starter
solenoid
and
starting motor (WP 0177 2. If continuity is indicated, go to
step d.
If starting motor is still
d. Inspect and clean ground
inoperative, replace starting
connections on back of
motor (WP 0071 00) and go to
starting motor and tighten
Malfunction 5, Test 4.
nut.
3. Test starter circuit source
voltage.
a. Place battery disconnect
switch in OFF position.
b. Set
to
appropriate voltage range
c. Connect
positive lead to BAT
terminal on solenoid and
negative lead to chassis
ground.
|