TM 5-2410-233-10
TROUBLESHOOTING PROCEDURES
Table 1. Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE
1. Engine Fails to Crank When Switch is
1. Check battery disconnect
Turn battery disconnect switch
Turned to Start.
switch for ON position.
ON.
2. Check circuit breaker reset
Push circuit breaker reset button
button on dash panel.
on dash panel.
3. Check circuit breaker reset
Push circuit breaker reset button
button on left side of engine
on left side of engine firewall.
firewall.
If electrolyte level is below top of
4. Check to see if electrolyte
level in batteries is over plates
plates, add distilled water until
level is 3/8 in. (9.5 mm) above
tops of plates. Notify Unit
Maintenance
to
recharge
batteries.
Notify Unit Maintenance.
5. Inspect for loose, corroded or
broken battery cables or
terminals.
2. Engine Fails to Start When Engine Cranks.
1. Check governor control lever
Move lever to correct starting
for correct starting position
position.
2. Check for empty fuel tank.
Fill tank if empty or low (WP
3. Ensure fuel shutoff valve is all
Turn fuel shutoff valve all the
the way ON.
way ON.
3. Engine Hard to Start or Stalls Frequently.
1. Check air cleaner service
If red band is showing, service air
indicator reading.
cleaner
primary
elements.
Remember to reset air cleaner
service indicator (WP 0014 00).
2. Check for clogged fuel filter.
Check fuel pressure gage reading.
Notify Unit Maintenance for
filter servicing if gage needle is in
RED zone.
3. Check for low fuel supply.
Fill tank with proper grade of fuel
|