High pressure hydraulics [oil under 3700 psi
S
(25,512 kPa) pressure] operate this
equipment. Refer to truck operator and
maintenance manuals for hydraulic oil
pressure. Never disconnect any hydraulic line
or fitting without first dropping pressure to
zero. Failure to comply may result in injury to
personnel.
Fuel and oil are slippery and can cause falls.
S
To avoid injury, wipe up spilled fuel or oil with
rags.
NOTE
Use drain pan to catch leaking hydraulic oil.
PRESSURE TEST
(1) Remove eight screws, lockwashers,
washers and left side noise panel.
Discard lockwashers.
(2) Remove six screws, lockwashers
and LHS control box cover. Discard
lockwashers.
(3) Remove dust cap from multifunction
manifold, port G9.
(4) Connect pressure gauge to
multifunction manifold, port G9.