TM 9-2320-364-34-1
22. OSS DISABLES FUNCTIONS (CONT).
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits a direct short may result. Damage to equipment, injury or death to personnel may result.
Do not stand under crane. Mechanical failure and operator error can cause injury or death to
personnel.
CALIBRATION TEST (CONT).
(8) Start engine (TM 9-2320-364-10).
(9) Set WINCH/CRANE switch to
CRANE position.
(10) Set hydraulic selector switch to
CRANE/SRW position.
(11) Set crane main POWER switch to
ON position.
(12) Using TELE control lever, telescope
boom out completely.
(13) Adjust clarity of test unit display
using control knob on bottom of test
unit.
(a) If test unit does not indicate
between 22.0 and 23.0 ft
(6.7 to 7 m), go to Step 4 of this
Fault.
(b) If test unit indicates
between 22.0 and 23.0 ft
(6.7 to 7 m), go to Step (14)
below.
(14) Using TELE control lever, retract
boom completely.
(a) If test unit does not indicate
between 6.8 and 7.8 ft
(2.1 to 2.4 m), go to Step 4 of
this Fault.
(b) If test unit indicates between 6.8
and 7.8 ft (2.1 to 2.4 m), perform
Steps (15) through (22) below
and replace tension load cell
(Para 16-25).
Continued on next page.
2-714
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |