TM 9-2320-364-34-1
All personnel must stand clear during lifting operations. A swinging or shifting load may cause injury
or death to personnel.
NOTE
Boom should be telescoped out completely
and at five degrees. Check that mast is up
completely.
Test weight can be 10 lbs (4.5 kg).
LOAD TEST
(1) Using HOIST control lever, lift 3900 lb
(1771 kg) load from ground
(TM 9-2320-364-10).
(a) If crane lifts load and OSS does
not lock out crane functions,
stow crane, perform Steps
(2) through (4) and go to Step 7 of
this Fault.
(b) If OSS locks out crane functions,
perform Steps (2) through (4) and
replace OSS box (Para 6-8).
(2) Set crane main POWER switch to
OFF position.
(3) Set hydraulic selector switch to OFF
position.
(4) Turn OFF ENGINE switch.
|