TM 9-2320-364-34-1
21. CRANE FAILS LOAD TEST (CONT).
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits a direct short may result. Damage to equipment, injury or death to personnel may result.
Do not stand under crane. Mechanical failure and operator error can cause injury or death to
personnel.
Hooked test unit connector must not contact
other transistor wire or damage to
OSS and test unit will result.
NOTE
When connecting test unit connector to display
receptacle, test unit connector white wire
receptacle must be engaged in the third pin
from the right (fourth pin from left) of display
receptacle.
OPERATION TEST (CONT).
(12) Remove four screws, preformed
packings, and cover from OSS box.
Discard preformed packings.
(13) Remove safety lock seal from two
screws.
(14) Remove four screws and cover from
central processor unit.
(15) Connect test unit connector to
display receptacle.
(16) Connect test unit red connector to
RH inductive coil wire.
(17) Connect test unit black connector to
LH inductive coil wire.
(18) Connect test unit hooked connector
to transistor middle wire.
(19) Tie strap test unit connector cable
to post.
Continued on next page.
|