Click here to make tpub.com your Home Page

Page Title: CRANE FAILS LOAD TEST. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits a direct short may result. Damage to equipment, injury or death to personnel may result.
Do not stand under crane. Mechanical failure and operator error can cause injury or death to
personnel.
OPERATION TEST (CONT).
(20) Start engine (TM 9-2320-364-10).
(21) Set WINCH/CRANE switch to
CRANE position.
(22) Set hydraulic selector switch to
CRANE/SRW position.
(23) Turn ON crane main POWER
switch.
(24) Adjust clarity of display using
control knob on bottom of test
unit.
(a) If display does not come on,
perform Steps (25) through (27)
and repair green wire
(see schematic Fig 2-7) or
replace harness (Para 6-29)
from OSS box top connector to
crane main junction box.
(b) If display comes on, go to
Step 2 of this Fault.
(25) Set crane main POWER switch to
OFF position.
(26) Set hydraulic selector switch to
OFF position.
(27) Turn OFF ENGINE switch.
2-677