TM 9-2320-364-34-1
High pressure hydraulics [oil under 3000 psi (20,685 kPa) pressure] operate this equipment. Refer to
vehicle operator and maintenance manuals for hydraulic oil pressure. Never disconnect any hydraulic
line or fitting without first dropping pressure to zero. Failure to comply may result in injury to personnel.
Fuel and oil are slippery and can cause falls. To avoid injury, wipe up spilled fuel or oil with rags.
NOTE
Use a drain pan to catch leaking hydraulic oil.
FLOWMETER TEST
(1) Disconnect hose 2918 from main
hydraulic filter.
(2) Connect adapter hose to filter.
(3) Connect adapter hose to flowmeter
OUT port.
(4) Connect adapter hose to hose 2918.
(5) Connect adapter hose to flowmeter
IN port.
(6) Open flowmeter load valve.
(7) Start engine (TM 9-2320-364-10).
(8) Set WINCH/CRANE switch to
CRANE position.
(9) Set hydraulic selector switch to
CRANE/SRW position.
(10) Set crane POWER switch to
ON position.
(11) Observe and record gpm (lpm)
measured.
(12) Hold BOOM control lever in UP
position.
(a) If an increase in flow is not
present, perform Steps (13)
through (18) below and replace
BOOM valve on four valve bank
(Para 16-26).
(b) If an increase in flow is
measured, perform Steps (13)
through (18) below and replace
OSS directional valve on four
valve bank (Para 16-26).
(13) Set crane POWER switch to
OFF position.
(14) Set hydraulic selector switch to OFF
position.
(15) Turn OFF ENGINE switch.
(16) Disconnect adapter hose from
hose 2918. Discard preformed
packing.
(17) Disconnect adapter hose from
return filter. Discard preformed
packing.
(18) Connect hose 2918 with preformed
packing to filter.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |