14. BOOM DOES NOT RAISE OR RAISES SLOWLY (CONT).
5.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Are
Flowmeter test.
Unit Troubleshooting
on Page 2-599
0 gpm
tasks completed.
REASON FOR QUESTION
Boom lowers.
(0 lpm)
Four valve bank OK.
measured
If piston seals are faulty in
at four valve bank with boom
cylinder that is active (not
POSSIBLE PROBLEMS
lift cylinder on OSS side of
isolated from circuit), more than
0 gpm (lpm) will be measured. If
boom isolated from (discon-
Lift cylinder faulty.
piston seals are faulty in cylinder
nected) other boom cylinder?
that is isolated from
(disconnected) circuit, 0 gpm
(lpm) will be measured.
Replace cylinder not
on OSS side of boom
(Para 16-6).
NO
Verify repair, go to
Step 6 of this Fault.
YES
Replace cylinder on
OSS side of boom
(Para 16-6).
Verify repair, go to
Step 6
of this Fault.