The LHS hydraulic system operates at oil pressures up to 3675 psi (25,339 kPa). Never disconnect any
S
hydraulic line or fitting without first dropping pressure to zero. Failure to comply may result in serious
injury or death to personnel.
Fuel and oil are slippery and can cause falls. To avoid injury, wipe up spilled fuel or oil with rags.
S
FLOWMETER TEST
(1) Disconnect pressure hose 2777
female quick disconnect from LHS
control box male quick disconnect.
(2) Connect adapter hose of same size
to hose 2777.
(3) Connect adapter hose of same size
to LHS control box male quick
disconnect.
(4) Connect flowmeter IN port to
adapter hose connected to
hose 2777.
(5) Connect flowmeter OUT port to
adapter hose connected to LHS
control box male quick disconnect.
(6) Completely open flowmeter load
valve.
(7) Set flowmeter to high.
(8) Start engine (TM 9-2320-364-10).
(9) Set hydraulic selector switch to
AUTO position.
(10) Raise engine speed to full
throttle and observe flowmeter.
(a) If 28 to 32 gpm (106 to 121 lpm)
are not present, perform Steps
(11) and (15) below and go to
Step 5 of this Fault.
(b) If 28 to 32 gpm (106 to 121 lpm)
are present, perform Steps (11)
and (15) below and go to
Step 6 of this Fault.
(11) Set hydraulic selector switch to OFF
position.
(12) Turn OFF ENGINE switch.
(13) Remove adapter hose 2777 from
female quick disconnect.
(14) Remove adapter hose 2777 from
LHS control box male quick
disconnect.
(15) Connect quick disconnect
hose 2777.
|