TM 9-2320-364-34-1
9. LHS DOES NOT OPERATE OR OPERATES SLOWLY (CONT).
4.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Unit Troubleshooting tasks
Flowmeter test.
on Page 2-377
completed.
Winch and crane operates.
REASON FOR QUESTION
Multifunction manifold shuttle
Are 30 gpm (114 lpm)
valves OK.
If LHS differential pressure valve
measured at multifunction
or orifice at port C2 is faulty, 28
POSSIBLE PROBLEMS
to 32 gpm (106 to 122 lpm) will
manifold, port C2?
not be delivered to LHS.
Multifunction manifold, port C2
orifice faulty.
LHS differential pressure
sensing valve faulty.
Free flow solenoid valve faulty.
LHS ventable relief valve faulty.
Go to Step 5 of this
NO
Fault.
YES
Go to Step 6 of this
Fault.
2-376
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |