TM 9-2320-364-34-1
The LHS hydraulic system operates at oil pressures up to 3675 psi (25,339 kPa). Never disconnect any
S
hydraulic line or fitting without first dropping pressure to zero. Failure to comply may result in serious
injury or death to personnel.
Fuel and oil are slippery and can cause falls. To avoid injury, wipe up spilled fuel or oil with rags.
S
VISUAL INSPECTION
(1) Remove shuttle valve C from
multifunction manifold.
(2) Remove and discard three preformed
packings and two packing retainers.
(3) Shake shuttle valve and listen for ball
to rattle.
(a) If check ball does not rattle, clean
or replace shuttle valve
(Para 17-18).
(b) If check ball does rattle, fault not
corrected. Perform Steps (4)
through (8) below and notify
supervisor.
(4) Lubricate three preformed packings
and two packing retainers with
hydraulic oil and install on shuttle
valve.
(5) Install shuttle valve C.
(6) Connect quick disconnect
hose 2917.
(7) Install left side noise panel, eight
lockwashers and screws.
(8) Install four screws, lockwashers and
LHS control box cover.
|