The LHS hydraulic system operates at oil
S
pressures up to 3675 psi (25,339 kPa).
Never disconnect any hydraulic line or
fitting without first dropping pressure
to zero. Failure to comply may result in
serious injury or death to personnel.
Fuel and oil are slippery and can cause
S
falls. To avoid injury, wipe up spilled
fuel or oil with rags.
FLOWMETER TEST
(1) Disconnect hose 2917 male quick
disconnect from LHS control box
female quick disconnect.
(2) Disconnect hose 2888 from LH main
cylinder manifold adapter
port VA.
(3) Connect adapter hose to hose 2888.
(4) Connect adapter hose to main
cylinder manifold adapter port VA.
(5) Connect flowmeter OUT port to
adapter hose connected to
hose 2888.
(6) Connect flowmeter IN port to
adapter hose connected to LH main
cylinder manifold, port VA.
(7) Completely open flowmeter
load valve.
(8) Set flowmeter to LOW scale.
(9) Connect quick disconnect
hose 2917.
(10) Start engine (TM 9-2320-364-10).
(11) Set hydraulic selector switch
to MAN MF position.