6. MIDDLE FRAME DOES NOT LOAD (CONT).
The LHS hydraulic system operates at oil
S
pressures up to 3675 psi (25,339 kPa).
Never disconnect any hydraulic line or
fitting without first dropping pressure
to zero. Failure to comply may result in
serious injury or death to personnel.
Fuel and oil are slippery and can cause
S
falls. To avoid injury, wipe up spilled
fuel or oil with rags.
FLOWMETER TEST (CONT).
(12) With the aid of an assistant,
observe flowmeter while holding
joystick in LOAD position.
(a) If more than 0 gpm (lpm) are
present, perform Steps (13)
through (20) below and replace
LH main cylinder (Para 17-15).
(b) If 0 gpm (0 lpm) are present,
LH main cylinder is OK.
(13) Set hydraulic selector switch to
OFF position.
(14) Turn OFF ENGINE switch.
Continued on next page.