TM 9-2320-364-34-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
CONTINUITY TEST
(1) Disconnect sensor harness assembly
from solenoid wiring harness
assembly connectors.
(2) Connect jumper wire between
terminals of sensor harness assembly
double connector.
(3) Is there continuity between the
sensor harness assembly single
terminals?
(a) If there is no continuity, replace
sensor harness assembly
(Para 7-6).
(b) If there is continuity, sensor
harness assembly is OK.
|