TM 9-2320-364-34-1
1. LOW OIL LEVEL SENSOR CIRCUIT FAULTY (CONT).
2.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Continuity test.
Unit Troubleshooting tasks
on Page 2-119
STE/ICE-R #91.
completed.
ATEC code 12 in memory.
REASON FOR QUESTION
Truck wiring OK.
Is continuity measured
Low oil level sensor OK.
between sensor harness
If there is no continuity, sensor
harness assembly is faulty.
assembly single connectors?
POSSIBLE PROBLEMS
Sensor harness assembly
faulty.
Solenoid wiring harness
assembly faulty.
ATEC ECU faulty.
Replace sensor
harness assembly
NO
(Para 7-5).
Verify repair, go to
Step 4 of this Fault.
YES
2-118
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |