TM 9-2320-364-20-1
Section V. DIAGNOSTIC DATA READER INFORMATION (Cont.)
B.2 INACTIVE CODES
Inactive Codes are faults that have occurred previously. The display for each code is as follows:
SCREEN #1
SCREEN #2
Line 1:
MID:XXX ENGINE XX
Line 5:
1st:
Last:
Line 2:
PID Description
Line 6:
Total#:
Line 3:
FMI Description
Line 7:
Total Time:
Line 4:
↑I## PID:XXX FMI:XX↓
Line 8:
Min/Max:
NOTES:
(1) I##:
Numerical Count of Inactive Codes
(2) 1st:
First occurrence of the diagnostic code in engine hours
(3) Last:
Last occurrence of the diagnostic code in engine hours
(4) Total#:
Total number of occurrences
(5) Total Time:
Total engine seconds that the diagnostic code was active
(6) Min/Max:
Minimum/Maximum value recorded during diagnostic condition
B.3 CLEAR CODES
This function allows diagnostic codes stored in the ECM(s) to be erased. An audit trail of when the codes were last erased in
engine hours will be displayed.
|