2-14. DDEC III/IV TROUBLESHOOTING (CONT).
Section V. DIAGNOSTIC DATA READER INFORMATION (Cont.)
A.
ENGINE DATA LIST
The Engine Data List menu selection displays the set of DDEC III/IV data that pertain to the operation of the engine and
vehicle.
NOTES:
(1) Engine data list values that are displayed as `N/A' (not available) typically indicate that the sensor(s) and/or function is not
part of the engine configuration, or the data is not being transmitted by the DDEC III/IV ECM. These are not included in the
following lists.
(2) Engine sensor values that are displayed as `FAIL' is an indication that a FMI 3 (Sensor Voltage High) or a FMI 4 (Sensor
Voltage Low) diagnostic condition is currently active for that sensor(s).
ACTIVE CODES
Definition: Indicates the presence of a condition(s) that causes the check engine light to be on.
Typical Range: YES or NO
INACTIVE CODES
Definition: Indication that past active codes have been stored in the ECM memory.
Typical Range: YES or NO
ENGINE RPM
Definition: Indicates engine RPM as determined by the Timing Reference Sensor (TRS).
Typical Range: 0 to 2500 RPM
PULSEWIDTH
Definition: Fuel Pulse Width -- Number of degrees crankshaft rotation that the EUI's control valve is closed and fuel is
entering the cylinder
Typical Range: 0.0 to 25.5 Degrees
BOOST PSI
Definition: Boost Pressure -- Pressure of air measured by the Turbo Boost Sensor (TBS) downstream on the
compressor discharge side of the turbocharger.
Typical Range: (0.0 to 43.5 PSI) or (0 to 305 KPa)
ENG LOAD PCT
Definition: Indicates the percent engine load calculated from engine speed and torque.
Typical Range: 0 to 100%
TORQUE LB-FT or NM
Definition: Indicates the amount of torque available at the engine flywheel. Negative torque values will be displayed
with a minus sign in front of the value.
Typical Range: --9999 to 9999 LB-FT / --9999 to 9999 NM
TPS CNTS
Definition: Throttle Position Sensor (TPS) Counts (CNTS). Indicates the analog to digital (A/D) conversion of (0 to 5
volts) from the TPS to (0 to 1024 counts) that the ECM uses to compute the percent throttle opening.
Typical Range: (0 to 1024 Counts) or N/A
TPS PCT
Definition: Indicates the percent opening of the Throttle Position Sensor (TPS).
Typical Range: 0 to 100%