TM 9-2320-364-20-1
2-14. DDEC III/IV TROUBLESHOOTING (CONT).
Section IV. TROUBLESHOOTING CHARTS (Cont.)
E. FLASH CODE:
62
J1587 CODE:
S026 3/4 - AUXILIARY OUTPUT SHORT TO BATTERY,
AUXILIARY OUTPUT OPEN CIRCUIT
NOTE - This chart is only to be used if:
-
1) All basic mechanical checks and physical inspections have been performed with no problem found; and,
2) Diagnosis of DDEC III/IV was started at step START-1, pg 2-539, and you have now been referred here.
STEP/SEQUENCE
62-1
Determine SAE Codes
26-3
Auxiliary ouput
#1 short to battery (ckt 988).
26-4
Auxiliary ouput
#1 open circuit (ckt 988).
|