E. FLASH CODE:
52
J1587 CODE:
S254 12 ANALOG TO DIGITAL (A/D) CONVERSION FAILURE
NOTE - This chart is only to be used if:
-
1) All basic mechanical checks and physical inspections have been performed with no problem found; and,
2) Diagnosis of DDEC III/IV was started at step START-1, pg 2-539, and you have now been referred here.
STEP/SEQUENCE
RESULT
WHAT TO DO NEXT
52-1
Multiple Code Check
Were there any other codes
Yes.
Service other codes first.
besides 254/12?
No.
Replace ECM (para 7-57). Then
go to START-1, pg 2-539.
|