TM 9-2320-364-20-1
2-14. DDEC III/IV TROUBLESHOOTING (CONT).
Section IV. TROUBLESHOOTING CHARTS (Cont.)
E. FLASH CODE:
36
J1587 CODE:
P100 4 - OIL PRESSURE CIRCUIT FAILED LOW (LOW VOLTAGE)
NOTE - This chart is only to be used if:
-
1) All basic mechanical checks and physical inspections have been performed with no problem found; and,
2) Diagnosis of DDEC III/IV was started at step START-1, pg 2-539, and you have now been referred here.
STEP/SEQUENCE
RESULT
WHAT TO DO NEXT
36-1
Multiple Code Check
Were there any other active
No other codes.
Go to 36-2.
codes besides Code 100/4?
Yes, any or all
Go to ENG5V-1 (page 2-761).
of the following codes:
110/3 or 4, 175/3 or 4,
174/3 or 4, 102/3 or 4,
100/3, 187/4, 91/4.
Yes - but none
Go to 36-2.
of the above.
36-2
Sensor Check
Turn ignition off.
Code 100/3 (and
Check to be sure ECM and OPS
Disconnect OPS connector
any codes except
connectors are wired properly.
(para 7-68) and install a jumper
Code 100/4).
If wired properly then go to 36-3.
wire between sockets B and C
of the OPS connector.
Code 100/4 (and any
Go to 36-4.
Turn ignition on.
other codes).
Read active codes.
If active Code 100/3 or 4 exists,
No codes.
Go to 36-4.
go to RESULT column.
If no active Code 100/3 or 4 exists,
start and run engine
(TM 9-2320-364-10) until either
active Code 100/3 or 4 appears
or the COOLANT TEMP or
OIL TEMP on the DDR has been
greater than 60 degrees
C (140 deg F) for more than
1 minute.
36-3
Check OPS Connectors
Turn ignition off.
Inspect terminals at the OPS
Terminals and
Replace OPS (para 7-68).
connectors (sensor side and
connectors are okay.
Then go to 36-30.
harness side) for damage; bent,
corroded, and unseated pins or
Problem found.
Repair terminals/connectors
sockets.
(para 7-101). Then go to 36-30.
|